Thermal Imaging across south-east Queensland.

Thermal imaging services that spot overheating switchboards and equipment before they become a breakdown.

Fully licensed & compliant
Commercial & industrial focus
Rapid breakdown response
50+ years combined experience

What thermal imaging covers

Thermal imaging finds heat building up in a switchboard or piece of equipment well before it becomes visible damage or a failure.

Using a thermal camera, we scan switchboards, connections and equipment for hot spots that point to a loose connection, an overloaded circuit or a failing component, then report exactly what we find and where.

It's a non-invasive scan, so it doesn't mean shutting your site down to carry it out.

How we deliver it

We scan your switchboard and equipment while it's running under normal load, since that's when a developing fault actually shows up as heat.

Findings are reported with the thermal image alongside a plain explanation of what it means and what to do about it, so you're not left interpreting a picture on your own.

Thermal Imaging

What is included

The exact scope depends on your site and switchboard count. Get in touch for a tailored quote.

Switchboard Thermal Scans

Thermal imaging of main switchboards and electrical equipment to identify unusual heat patterns while equipment is operating.

Distribution Board Inspections

Scanning of distribution boards, protective devices and internal components for signs of developing electrical faults.

Connections and Terminations

Identification of heat around electrical connections and terminations that may indicate looseness, deterioration or increased resistance.

Overloaded and Unbalanced Circuits

Detection of abnormal temperatures that may be associated with overloaded equipment, circuit issues or uneven electrical loading.

Early Fault Detection

Identification of developing problems before they result in equipment damage, unexpected shutdowns or more extensive repairs.

Non-Invasive Testing

Inspection of operating electrical equipment without interrupting the site's normal power supply or production activities.

Thermal Imaging Reports

Clear reports containing thermal and reference images, identified concerns and recommended actions for each inspected item.

Rectification and Follow-Up Scanning

Repair of confirmed electrical defects where authorised, followed by additional scanning to verify the result.

The standards this work is measured against

Compliance isn't optional on a commercial or industrial site. Our work is measured against the same standards inspectors and insurers check against.

AS/NZS 3760

In-service safety inspection and testing of electrical equipment

AS/NZS 3012

Electrical installations, construction and demolition sites

AS 2293

Emergency escape lighting and exit signs

AS/NZS 3000

Electrical installations, the wiring rules

Why it matters on a commercial site

A hot connection can sit inside a switchboard for months before it trips a breaker or starts a fire, and by then the cost is a lot higher than a scan would have been.

Catching it early through thermal imaging means a planned repair on your terms, rather than an unplanned breakdown on someone else's.

Because the scan happens while the site is running, it finds the faults that only appear under load. An inspection of a de-energised board cannot show a connection that heats up only when the plant it feeds is working.

Scanning the same boards periodically is more useful than scanning them once, because what matters is the change. A connection that has warmed since the last scan tells you something a single reading never can.

Where we do thermal imaging

The same licensed team covers every area we work in across south-east Queensland, so the standard does not change with the postcode. Choose an area to see how we work there.

Consistent standards across every job.

Commercial &
Industrial Experts

From shopping centres to industrial sites, we understand the pressures of a live commercial environment.

Licensed &
compliant

Fully licensed in Queensland and New South Wales, and Cm3 certified for controlled commercial sites.

Service to
major projects

From routine maintenance to large scale fitouts and new builds, we scale to the size of the job.

One point
of contact

One team stays across your site, so you are not explaining the job again to someone new.

Trusted on site, trusted in the office

1 / 5

Trusted across south-east Queensland

Trusted by property managers, retailers, builders and body corporates across the region.

Retail First
CBRE
Australia Fair
Savills
Logan Hyperdome
First Asset Management
homeWORLD Helensvale
Ray White Commercial
Fairfield Gardens
Mt Gravatt Plaza
Faith Lutheran College Redlands
Future Civil Group
IGA
NNB Group

Common questions

It picks up heat building up in switchboards, connections or equipment, often before there's any visible sign of a problem.

No. It's a non-invasive scan carried out while your equipment is running under normal load.

It depends on your equipment and site risk, get in touch and we'll recommend a sensible schedule.

A report with the thermal images and a plain explanation of what was found and what, if anything, needs attention.

It's a useful addition to maintenance, not a replacement, the two work well together rather than instead of each other.

Compliance guides & insights

What is test and tagging?
Testing
19 Nov 2026

What is test and tagging?

Test and tagging is the routine inspection and electrical testing of plug-in equipment, followed by a tag on the lead that records the result.

Switchboard Compliance & Upgrade Guide
Compliance
12 Jul 2026

Switchboard Compliance & Upgrade Guide

Boards are rarely replaced because they fail. They are replaced because the building changed around them and the board never caught up.

Ready when you are.

Tell us what's going on and we'll get back to you with the right next step, whether that's a quote, a site visit or a discussion about your requirements.

1300 JCS NOW1300 527 669